This activity is intended for those who are interested to participate in the competition and challenge themselves to achieve high quality plans, whether they have already participated in the first competition (LT Breast case) or would like to join our community.

 

In this follow-up replan activity, the participants will plan this tough LT Breast case using the guidance of the best planners in their corresponding TPS. The materials shared will be considered as guidelines or directions for participants to achieve high quality plans.

Primary Radiation Oncologist
Noha Jastaniyah, MD, FRCPC, ABR

Radiation Oncology Consultant
Specialty: Breast Cancer and Gynecological Malignancies
Radiation Oncology Department
King Faisal Specialist Hospital and Research Centre

Left Breast Cancer

  • Case diagnosis Left Breast Cancer
  • Treatment Site: Left breast with axilla and supraclavicular lymph nodes
  • Target: PTV_TOT_EVAL
  • Dose Prescription: 50.0 Gy in 25fr
  • Protocol followed: RTOG-1304 (Criteria squeezed more!)
  • Techniques 3D-CRT, IMRT, VMAT
  • General plan criteria were set: # of field, single isocenter, energies, etc
  • Dose calculation grid should be less then 3mm
  • General plan should be deliverable (no couch / patient collision)

2016 Radiotherapy Plan Competition

Rank Name Score Working Place Country Technique TPS Linac
1 Hugues Mailleux 98.2 Institut Paoli-Calmettes France VMAT RayStation Elek-Versa
2 Fazal Khan 98.1 Mass. Gen. Hospital USA VMAT RayStation Elek-Agility
3 Mikel Byrne 96.8 ROC-Sydney Australia VMAT RayStation Var-TrueB
4 Cameron Ditty 96.7 RaySearch – America USA VMAT RayStation Elek-Versa
5 Mustapha Khodri 95.4 ORLAM France VMAT RayStation Var-Clinac
6 Simon Heinze 94.6 Kantonsspital Sr. Gallen Switzerland Helical-IMRT TOMO TOMO
7 Timothee Ruef 94.0 Pôle d’imagerie et cancérologie du Pont St Vaast France VMAT Pinnacle Elek-Versa
8 Ludovic Michon 93.9 CRT Versailles France VMAT Pinnacle Elek-Versa
9 Saad Aldelaijan 93.6 KFSH&RC – Riyadh Saudi Arabia VMAT Eclipse Var-TrueB
10 Perumal Murugan 92 Sri Shankara Cancer Hospital & Research Centre India IMRT Eclipse Var-TrueB
11 Le Bourhis Julien 91.5 Centre Clinique de la Porte de Saint Cloud France VMAT Pinnacle Elek-Versa
12 Laurent Tantôt 90.6 Hôpital Maisonneuve-Rosemont Canada VMAT RayStation Elek-Infinity
13 Craig Koontz 90.1 Comprehensive Cancer Centers of Nevada USA VMAT Pinnacle Var-21iX
14 Nguyen Daniel 90.1 ORLAM – MACON France VMAT RayStation Var-Clinac
15 Vanessa Magliari 89.4 Rush-Copley USA IMRT Eclipse Var-TrueB
16 Rolf Wiehle 89.3 Klinik für Strahlenheilkunde, Uniklinik Freiburg Germany VMAT Eclipse Var-Clinac
17 Julien Rolland 87.1 Chicas France VMAT RayStation Elek-Versa
18 Jansen Mendez 87.1 Makati Medical Center Philippines Helical-IMRT TOMO TOMO
19 Dmytro S Synchuk 84.4 Ukrainian Center of Tomotherapy Ukraine Helical-IMRT TOMO TOMO
20 Brett Sloman 84.1 Elekta USA VMAT Monaco Elek-Versa
21 Auzac Guillame 82.9 Gustave Roussy France Helical IMRT TOMO TOMO
22 Rui Silva 82.4 Lenitudes Medical Center Portugal VMAT Monaco Elek-Versa
23 Luke Mackowiak 81.6 Monongahela Valley Hospital USA VMAT Monaco Elekta
24 Vaclav Bednar 80.8 Svet zdravia, a.s. Slovakia 3D-CRT Eclipse Var-Clinac
  • The highest score was 98.2/100, top planners were from different continents
  • Around (21) planners scored above 80/100

Treatment Planning Systems

Participants per country

Hugues Mailleux

Hugues Mailleux

Score: 98.2 / 100
Job Title: Medical Physicist
Hospital: Institut Paoli-Calmettes
Years of Experience: 20
Technique: VMAT
TPS: RayStation
Country: France

Fazal Khan

Score: 98.1 / 100
Job Title:Proton Dosimetrist
Hospital: Massachusetts General Hospital
Years of Experience: 7
Technique: VMAT
TPS: RayStation
Country: USA

Mikel Byrne

Score: 96.8 / 100
Job Title: Medical Physics Specialist
Hospital: ROC Wahroonga
Years of Experience: 7
Technique: VMAT
TPS: RayStation
Country: Australia

Cameron Ditty, MSc, DABR

Score: 96.7 / 100
Job Title: Senior Physicist Specialist
Hospital: RaySearch Americas
Years of Experience: 13
Technique: VMAT
TPS: RayStation
Country: USA

Khodri Mustapha

Score: 95.4 / 100
Job Title: Medical Physicist
Hospital: ORLAM
Years of Experience: 23
Technique: VMAT
TPS: Raystation
Country: France

Simon Heinze

Score: 94.6 / 100
Job Title: Medical Physicist SSRMP
Hospital: Kantonsspital Sr. Gallen
Years of Experience: 5
Technique: VMAT
TPS: Tomotherapy
Country: Switzerland

Timothee Ruef

Score: 94.0 / 100
Job Title: Medical Physicist
Hospital: Pôle d’imagerie et cancérologie du Pont St Vaast
Years of Experience: 3
Technique: VMAT
TPS: Pinnacle
Country: France

Simon Heinze

Score: 93.9 / 100
Job Title: Medical Physicist
Hospital: CRT Versailles
Years of Experience: 6
Technique: VMAT
TPS: Pinnacle
Country: France

Saad Aldelaijan

Score: 93.6 / 100
Job Title: Medical Physicist
Hospital: King Faisal Specialist Hospital & Research Centre
Years of Experience: 3
Technique: VMAT
TPS: Eclipse
Country: Saudi Arabia

Perumal Murugan

Score: 92.0 / 100
Job Title: Medical Physicist
Hospital : Sri Shankara Cancer Hospital & Research Centre
Years of Experience: 8
Technique: IMRT
TPS: Eclipse
Country: India

Le Bourhis Julien

Score: 91.5 / 100
Job Title: Medical Physicist
Hospital: Centre Clinique de la Porte de Saint Cloud
Years of Experience: 4
Technique: VMAT
TPS: Pinnacle
Country: France

What Are You Waiting For? Join Us Now